IMPORTANT: This guide should only be run if you have first attempted to use the PRO Connect PRO Hub FPGA Only update utility and were unsuccessful.
IMPORTANT: This guide should only be run if you have first updated your PRO Hub’s bootloader to v2.24.
STEP 1: Turn off your Hub’s power switch and disconnect all USB cables from your Hub.
...
STEP 2: Turn on your Hub’s power switch and wait 10 seconds.
...
STEP 3: After waiting 10 seconds, connect a USB Type B 2.0 cable from your computer to your PRO Hub.
...
STEP 4: Navigate to the HB_PRO drive in your computer’s file system.
...
STEP 5: Download the “ofile.rbf” file to the HB_PRO drive. You should replace the existing “ofile.rbf”. You cannot rename this file, it must be “ofile.rbf”. You can download the file by clicking on it here:
View file | ||
---|---|---|
|
STEP 6: You will also need to convert your CONFIG.TXT file and apply it to your Hub. Copy the CONFIG.TXT file from the HB_PRO drive to your Desktop on your computer.
...
STEP 7: Eject the HB_PRO drive from your computer.
...
STEP 8: Turn off your Hub’s power switch.
...
STEP 9: Disconnect the USB Cable from your Hub and wait 2 seconds.
...
STEP 10: After waiting 2 seconds, turn on your Hub’s power switch.
...
STEP 11: Wait for your Hub to show up in the PRO Connect Device list.
...
STEP 12: Navigate to the File Tab on the Hub’s Config page.
...
STEP 13: Import the CONFIG.TXT file from your computer’s Desktop and Apply that configuration.
CONGRATULATIONS YOUR INITIAL PRO HUB UPDATE IS COMPLETE!
...